Service GuideGIGABYTEGS-R12T4H2-RH 1U Rack Mount ServerDual Intel® Xeon LGA1366 Processor ServerboardRev. 1.0
10GS-R12T4H2-RH Rack Mount Server (Support RAID 0, 1, 1E) (Option)Super I/OController ITE IT8720F Super I/OFront I/O 2 X USB 2.0 connectorRea
11GS-R12T4H2-RH Rack Mount ServerPre-installation InstructionsPerform the steps below before you open the server or before you remove or replaceany co
12GS-R12T4H2-RH Rack Mount ServerRemove the chassis cover.Step 1 Loosen the screw on the front chassis cover.Step 2 Push down the indentation located
13Hardware Installation ProcessInstalling the ProcessorPlease make sure the CPU type and speed that are supported by the motherboard.Step 1 Raise the
14GS-R12T4H2-RH Rack Mount ServerInstalling the Heat SinkStep 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please wellre
15GS-R12T4H2-RH Rack Mount ServerInstalling the Memeory ModuleStep 1. Insert the DIMM memory module vertically into the DIMM slot, and push it down.S
16Hardware Installation ProcessCPU1CPU2123456789101213141617181115No. Code No. Code 1 DDR_P1C2D0 10 DDR_P0C0D2 2 DDR_P1C2D1 11 DDR_P0C0D1 3 DDR_P1C2D2
17Hardware Installation ProcessU-DIMM Population TableP0C0D0P1C0D0P0C0D1P1C0D1P0C0D2P1C0D2P0C1D0P1C1D0P0C1D1P1C1D1P0C1D2P1C1D2P0C2D0P1C2D0P0C2D1P1C2D1
18GS-R12T4H2-RH Rack Mount ServerR-DIMM Population TableP0C0D0P1C0D0P0C0D1P1C0D1P0C0D2P1C0D2P0C1D0P1C1D0P0C1D1P1C1D1P0C1D2P1C1D2P0C2D0P1C2D0P0C2D1P1C2
19Hardware Installation ProcessInstalling the PCI Expansion CardStep 1 Lift the riser bracket slightly, then pull it out from the server chassis.Step
PrefaceBefore using this information and the product it supports, please read the following general information.1. This Service Guide provides you wit
20GS-R12T4H2-RH Rack Mount Server345656
21GS-R12T4H2-RH Rack Mount ServerInstalling the Hard Disk DriveStep 1 Press the release button.Step 2 Pull the locking lever to remove the HDD tray.St
22Hardware Installation ProcessHDD Security LockThe HDD bays incorporate a security screw to prevent accidental HDD release.To engage the lock, turn t
23GS-R12T4H2-RH Rack Mount ServerInstalling and Replacing the FAN DuctStep 1 Remove the airducts from the chassis by pulling the rear edge in the dire
24Hardware Installation ProcessReplacing the FAN AssembllyStep 1 Remove thefan assemble pulling the rear edge in the direction of the arrowStep 2 Lift
25GS-R12T4H2-RH Rack Mount ServerReplacing the MotherboardStep 1 Remove the chassis cover. See Removing the Chassis Cover on page 12.Step 2 Remove the
26Hardware Installation ProcessReplacing the Power SupplyStep 1 Remove the fanduct from the chassis by pulling the rear edge.Step 2 Disconnect the t
27GS-R12T4H2-RH Rack Mount Server
28GS-R12T4H2-RH Rack Mount ServerReplacing the Chassis CoverStep 1 Replace the cover, and slide the chassis in the direction of the arrow until the
29GS-R12T4H2-RH Rack Mount ServerFront View of GS-R12T4H2-RHAppearance of GS-R12T4H2-RHNOTE! For Front LED description, please go to Front Panel LED I
3GS-R12T4H2-RH Rack Mount ServerTable of ContentsPreface...
System Appearance30Rear View of GS-R12T4H2-RH31 2 3 456 789 1. Power Module Connect the power cable to the socket. 2. PS/2 port Connect the keyboard a
31LED DescriptionFront Panel LED Indicator234156No Indicator 1 Powerstatus 2 System ID 3 Systemstatus 4 HDDactivityColor State DescriptionGreen On Sys
32GS-R12T4H2-RH Rack Mount ServerColor State DescriptionGreen On Link between system andnetwork or no accessGreen Blink Network accessGreen On Link be
33GS-R12T4H2-RH Rack Mount ServerLAN port LED IndicatorNo Name 1 Speedindicator2 Link/activityindicatorColor State DescriptionN/A Off 10Mbps con
34LED DescriptionHard Disk Drive LED Description Description HDD Prsent HDD access HDD failure HDD removed HDD connected and rebuilding data
35GS-R12T4H2-RH Rack Mount ServerGC-BS14U-RH Back plane board Components2143107511136891214151817161920 21 22 2324 25 26 27No Code Description 1 P2 Po
36GS-R12T4H2-RH Rack Mount ServerSystem Block DiagramVRD 11.1VRD 11.1CPU2Nehalem-EPProcessorLGA1366Port 1CPU1Nehalem-EPProcessorLGA1366Port 1QPIQPIINT
37GS-R12T4H2-RH Rack Mount ServerConnector Icon DescriptionSuggest IconDescriptionKeyboardVGAMouseLANCOMUSB
38Motherboard ComponontsGA-7TTSE-RH Motherboard ComponentMotherboard Placement and Jumper Setting234156910711121315142181618192022172324
39GS-R12T4H2-RH Rack Mount ServerItem Component1. Processor 1 socket2. Processor 2 socket3. SATA data cable cable connectors4. USB connector for inter
4Table of ContentAdvanced ... 47Processor Configuratio
40Jumper SettingJumper Setting2134567 1 ) BIOS_RVCR1 (BIOS Revocery jumper)1-2 close: Normal operation. (Default setting)2-3 close: Enable BIOS Recov
41GS-R12T4H2-RH Rack Mount Server 5 ) PASS_DIS1 (Skip Supervisor password jumper)111-2 Close: Normal operation. (Default setting)2-3 Close: Clear Su
42Jumper SettingExpansion Card Components DescriptionThe two riser cards installed in the PCI riser card bracket assembly povides support for both ful
43GS-R12T4H2-RH Rack Mount Server<> Move to previous item<> Move to next item<> Move to the item in the left hand<> Move t
44BIOS SetupGETTING HELPMain MenuThe on-line description of the highlighted setup function is displayed at the bottom of the screen.Status Page Setup
45GS-R12T4H2-RH Rack Mount ServerSystem Date Set the System Date. Note that the “Day” automatically changed after you set the date.System Time The tim
46BIOS SetupTotal MemoryThe BIOS determines how much total memory is present during the POST.
47BIOS SetupFigure 2: AdvancedAdvancedAbout This Section: AdvancedWith this section, allowing user to configure your system for advanced operation. Us
48GS-R12T4H2-RH Rack Mount ServerProcessor Configuration
49BIOS SetupProcessor ConfigurationThis category includes the Processor information of CPU Speed, Processor ID ,ProcessorL2 / L3 Cache, and QPI Freque
5GS-R12T4H2-RH Rack Mount ServerSafety, Care and Regulatory Information Important safety informationRead and follow all instructions marked on the pr
50GS-R12T4H2-RH Rack Mount ServerMachine CheckingEnabled Enable Machine Checking. (Default setting)Disabled Disable Machine Checking.Fast String Opera
51GS-R12T4H2-RH Rack Mount ServerProcessor Power ManagementFigure 2-1-1: Processor Power ManagementEIST (GV3) & C StateEnabled Enable EIST (GV3) a
52BIOS SetupSW_ALL In SW_ALL mode, the OS Power Manager is responsible for coordinatingthe P-state among loical processors with dependencies and must
53GS-R12T4H2-RH Rack Mount Serverstate. (Default setting)Disabled Disable CPU C6 Report.CPU C7 ReportEnabled Desire state for the Nehalem core C7 stat
54BIOS SetupMemory Configuration
55GS-R12T4H2-RH Rack Mount Server Memory InformationThese following items display all information of current Base Memory, Extended Memory,, and instal
56BIOS SetupAdvanced Chipset Configuration
57GS-R12T4H2-RH Rack Mount ServerFigure 2-3-1: Intel VT for Directed I/O (VT-d)
58BIOS SetupIntel VT for Directed I/O (VT-d)Enabled Intel VT for Directed I/O (VT-d). (Default setting)Disabled Disable Intel VT for Directed I/O (VT-
59GS-R12T4H2-RH Rack Mount Server2GB Select 2GB as granularity of PCI hole.QPI Control SettingsEnabled Enable QPI Control settings. (Default setting)D
6Safety Information* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.* Do not plug a modem or telephone cable i
60BIOS SetupPCI ConfigurationFigure 2-4: PCI ConfigurationOnboard LAN iSCSI Boot ROMEnabled Enable Onboard LAN iSCSI Boot ROM.Disabled Disable this f
61GS-R12T4H2-RH Rack Mount ServerLAN2Option ROMEnabled Enable onboard LAN2 device and initialize device expansionROM. (Default setting)Disabled Disab
62GS-R12T4H2-RH Rack Mount ServerSATA ConfigurationFigure 2-5: SATA Configuration
63BIOS SetupSerial ATAEnabled Enables on-board serial ATA function. (Default setting)Disabled Disables on-board serial ATA function. Native Mode Ope
64BIOS SetupAuto: Set parameters automatically. (Default setting)CD-ROM: Use for ATAPI CD-ROM drives or double click [Auto] to set all HDD parametersa
65BIOS SetupI/O DeviceConfigurationSerial Port A This allows users to configure serial prot A by using this option.Enabled Enable the configuration.
66GS-R12T4H2-RH Rack Mount ServerBase I/O Address/IRQ3F8/IRQ4 Set IO address to 3F8/IRQ4.2F8/IRQ3 Set IO address to 2F8/IRQ3. (Default setting)3E8/IRQ
67BIOS SetupBoot DeviceConfigurationBoot -time Diagnostic ScreenWhen this item is enabled, system will shows Diagnostic status when system boot.Enable
68GS-R12T4H2-RH Rack Mount ServerNumLockThis option allows user to select power-on state for NumLock.On Enable NumLock. (Default setting)Off Disable t
69BIOS SetupThermal and Acoustic ConfigurationFigure 2-8: Thermal and Acoustic ConfigurationOpen loop Thermal ThrottleEnabled Open loop Thermal Thrott
7GS-R12T4H2-RH Rack Mount Serverthe FCC.Your telephone company may make changes in its facilities, equipment, operations, or procedures thatcould affe
70GS-R12T4H2-RH Rack Mount ServerClose loop Thermal ThrottleEnabled Close loop Thermal Throttle. (Default setting)Disabled Disable Close loop Thermal
71GS-R12T4H2-RH Rack Mount ServerPowerFigure 3: PowerAfter Power FailureThis option provides user to set the mode of operation if an AC / power loss o
72BIOS SetupSecurityFigure 4: SecuritySet Supervisor PasswordYou can install and change this options for the setup menus. Type the password up to 6cha
73GS-R12T4H2-RH Rack Mount ServerSet User PasswordYou can only enter but do not have the right to change the options of the setup menus. Whenyou selec
74BIOS SetupServerFigure 5: Server
75GS-R12T4H2-RH Rack Mount ServerSystem Management
76BIOS SetupSystem ManagementThis category allows user to view the system management features. Including information ofMotherboard Hardware informatio
77GS-R12T4H2-RH Rack Mount ServerFigure 5-2: Console RedirectionConsole RedirectionConsole RedirectionIf this option is set to enabled, it will use a
78BIOS SetupThis option allows user to set the specified baud rate.Options 300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, 115.2K.Terminal TypeThis option
79GS-R12T4H2-RH Rack Mount ServerBootFigure 6: BootBoot Priority OrderThis field determines which type of device the system attempt to boot from afte
8Safety InformationNOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the totalload to be connected to a telephon
80BIOS SetupExitFigure 7: ExitAbout This Section: ExitOnce you have changed all of the set values in the BIOS setup, you should save yourchanges and e
81GS-R12T4H2-RH Rack Mount ServerLoad Settup Defaultif you highlight this item and press Enter, a dialog box asks if you want to install optimals
9Feature SummaryMotherboard GA-7TTSE-RHProcessor Supported Supports dual Intel® Xeon® processors Intel Xeon® Dual-Core/Quad-Core processor in L
Comentarios a estos manuales